AU

NZ

Healthcare Cooling

VITAL Health Solutions

Precision Water Cooling & Air Handling Units

Vital Technik specialises in advanced HVAC solutions for healthcare, going beyond comfort to meet the stringent requirements of medical facilities. Our expertise lies in cooling systems for MRI and CT scanners, combining process chillers with air conditioning to maintain critical temperature and humidity levels for optimal device functionality.

Our approach in healthcare is both highly customised and detailed, focusing on reliability for patient care and operational efficiency. Our innovative cooling solutions enhance sterile surgical environments and medical imaging areas, ensuring precise temperature and humidity control.

Our product range includes:

  • Medical Split Indoor Chillers
  • Outdoor Precision Air Cooled Chillers
  • Floor Standing Vertical Air Coolers with Humidity Control
  • Medical Grade AHUs featuring up to 100% fresh air regeneration and special filtration, suitable for any hospital environment.

Choose Vital Technik for innovative, precision cooling solutions, fostering a healthier tomorrow.

H Series AHU's for Operating Theatres; Radiology Bunkers & MRI's

Thanks to twenty years of experience, TECNAIR presents a new generation of H Series air conditioners dedicated to operating theatres and hospitals, where the primary objective is high air quality.

The H Series units, in their standard configuration, are complete with all adjustment components (heat recovery system, cooling, pre- and post-heating, humidification and dehumidification), sized for the treatment of full fresh air or with partial recirculation. A flexible configuration and a high number of accessories guarantee the use of H Series units for applications such as: operating theatres, laboratories and clean rooms, image diagnosis rooms, wards and intensive care.

CHARACTERISTICS

  • Compatibility with European Regulation 1253/2014/EU ErP NRVU 2018
  • TÜV certification according to DIN1946/4
  • Single block painted structure with epoxy resins 60µ RAL 9010
  • Panels with thermal and acoustic insulation system using 50 mm thick self-extinguishing material, equipped with handles with safety closing system and inspection window
  • Motorised dampers on external air intake and gravitational ones on exhaust
  • High levels of static pressure available based on the need for installing absolute terminal filters
  • Section for air suction from the rooms, partial recycle or total exhaust to the outside
  • Static or dynamic management of overpressure or depression in the controlled room compared to a reference environment
  • Room emergency negative pressure activation system
  • Three air filtration stages (external, supply and return). Tight seal filter and differential pressure switch supports for each filter
  • Easy to sanitise and sterilise. No risk for Legionella Pneumophila
  • Condensate drains of the independent sections and fitted with syphon that can be inspected
  • Electrical panel complete with adjustment and safety devices
  • SURVEYEVO control microprocessor with graphical display
  • EC FANS electronic fans
  • Hydronic heat recovery system with inverter-controlled pump with thermal by-pass function
  • R410A scroll compressors with inverter-controlled brushless DC motor
  • Electronic expansion valves EEV with SMART COOL system
  • Modulating 3-way/2-way valves
  • Anti-freeze safety system
  • Submerged electrode humidifier
  • Nighttime machine standby and load reduction system for UPS power supply
  • RS485 Modbus RTU slave board for interface with BMS (Building Management System)

ACCESSORIES

  • Rectangular silencers for duct installation designed for hospital environments and clean rooms
  • Motorised dampers on all outlets
  • Motorised air recirculation damper
  • Execution for external installation
  • Modulating two-way valves instead of three-way
  • Booster pump with anti-freeze function, for low outdoor temperatures
  • Direct expansion post-cooling circuit for cardiac surgery
  • System for regulating and distributing network steam
  • Constant pressure control in supply and return ducts
  • Remote or duct installation room temperature and humidity probes
  • Supply humidity probe
  • Display system showing the percentage of filter clogging
  • User terminal for remote installation
  • LED lighting inside the compartments and electrical panel
  • Power supply line with speed regulator for remote condenser
  • Condensation regulation with 0-10V signal for remote condenser with EC fans

Notes:
(1) The performances, declared according to UNI EN 14511-1:2018, do not consider the heat generated by the fans which must be added to the thermal load of the system. The performances refer to the following conditions: incoming air: 35°C-40% UR; heat recovery with glycol at 27%; water: 7/12°C.
(2) The performances, declared according to UNI EN 14511-1:2018, do not consider the heat generated by the fans which must be added to the thermal load of the system. The performances refer to the following conditions: incoming air: 35°C-40% UR; heat recovery with glycol at 27%; R410a coolant; condensation temperature: 45°C.
(3) External static pressure: 800 Pa.
(4) The sound pressure levels at a distance of 2 m, 1.5 m height, free field and with ducted supply outlets, declared according to UNI EN ISO 3744:2010.
(*) Direct expansion execution (OHA) only.

If you require on-site support with your air conditioning or chiller system, we offer 24/7 service to our contracted customers.

Contact us today to learn more about our commercial air conditioning and HVAC services.

Whether you need on-site service, installation, repairs, or maintenance, our team at Vital Technik is here to help.

Contact us today to learn more about our services or to schedule a consultation.